HGI Cleaning Standards

pumpout

Hydro-mechanical Grease Interceptor (HGI)

Pump all material out completely

Remove baffles and scrape clean

Clean and scrape inside of the trap

  1. Remove visible grease
  2. Remove ridge tar build up from the side of the HGI

Clean loose material from the lid

Replace baffle

Pump out residual debris

Refill with water to the bottom of the baffle

Note interceptor condition on pumpout report

  1. Missing baffle
  2. Holes in the trap
  3. Gasket in disrepair or missing
  4. Missing trap lid bolt(s)
  5. etc.

Replace lid

FOG & Pretreatment News

  • WSA Newsletter
  • National Resource Reference Guide
  • WSA Blog
  • PPRC Blog
  • PDI Standards and Info
  • Interceptor Sizing Tool
  • Interceptor Whisperer

Copyright © 2022 · WSA · Built on the Genesis Framework by CodeAmazon

PPRC does not and shall not discriminate on the basis of race, color, religion (creed), gender, gender expression, age, national origin (ancestry), disability, marital status, sexual orientation, or military status, in any of its activities or operations. These activities include, but are not limited to, hiring and firing of staff, selection of volunteers and vendors, and provision of services. We are committed to providing an inclusive and welcoming environment for all members of our staff, clients, volunteers, subcontractors, vendors, and clients.